PA 12 ATEX *

*Only available upon request

c-best pa12 phl

C.ESD tubes in Polyamide 12 have been developed using the latest nanotechnology in polymer engineering. This tube, antistatic and flexible, can be used in pneumatic and fluid transfer applications (ATEX):

  • Flammable fluids transfer
  • Pneumatic systems and tubes in explosive environments.

These tubes C.ESD could be classified ATEX II 2 G/D.

Cod. Ø Ext. Ø Int. Thickness Bend. Radius Work. Press. 23°C Burst press. 23°C Spec. surface. res. ISO 3915 Col.*
                NR
T2A004002 4 mm 2,5 mm 0,75 mm 19 mm 9 bar 36 bar 10x10 Ohm³
T2A006004 6 mm 4 mm 1 mm 35 mm 22 bar 67 bar 10x10 Ohm³
T2A008006 8 mm 6 mm 1 mm 40 mm 16 bar 48 bar 10x10 Ohm³
T2A010008 10 mm 8 mm 1 mm 60 mm 12 bar 37 bar 10x10 Ohm³
T2A012010 12 mm 10 mm 1 mm 85 mm 10 bar 31 bar 10x10 Ohm³
*other colours subject to stock availability. For a minimum quantity Castello by ARaymond produces according to RAL chart (RAL table) or customer's requirements.
TOLERANCE

Tolerance on external diameter:


Ø Ext 4 mm - 8 mm: +/- 0,10 mm
Ø Ext 10 mm - 12 mm: +/- 0,15 mm


Upon request Castello by ARaymond can deliver tubes with higher precision tolerances.


MARKING
Standard marking is:

8x1 mm - PA HIPHL - C.ESD - ATEX II 2 G/D - 06002177 - 19 - 064 - 10:30:32
TEMPERATURE RANGE
From -60° C
to + 130° C
CHEMICAL RESISTANCE
Check the table
ROLL SIZE

0025 25 mt
0050 50 mt
0100 100 mt

Tolerance on roll length +/- 2%
PRESSURE VARIATION
As function of temperature
% PRESS. TEMP
100% 23° C
87% 30° C
74% 40° C
64% 50° C
57% 60° C
52% 70° C
47% 80° C
44% 90° C
40% 100° C
36% 110° C
33% 120° C
30% 130° C
MATERIAL TECHNICAL DATA SHEET
Characteristic Test Method Unit C.ESD
E Modulus ISO 527 MPa 350
Tensile strength @ break ISO 527 MPa 35
Elongation @ break ISO 527 % >50
Impact strength (+23°C) ISO 179/2-1eU KJ/m² no break
Hardness Shore D ISO 868 - 63

It is forbidden to use Castello by ARaymond tubes and coils in food and medical applications.