PA 11 HL (RIGID)

c-best pa12 phl

PA11 HL C.BIO tubes are used in both industrial automation and automotive applications and they are made using Polyamide 11, a polymer produced from a renewable source (castor oil). PA11 HL rigid tubes are recommended for their resistance to high pressure.

Cod. Ø Ext. Ø Int. Thickness Bend. Radius Work. Press. 23°C Burst press. 23°C Col.*
              NR NT
T1R004025 4 mm 2,5 mm 0,75 mm 30 mm 62 bar 185 bar
T1R004002 4 mm 2 mm 1 mm 25 mm 89 bar 267 bar
T1R005003 5 mm 3 mm 1 mm 40 mm 67 bar 200 bar
T1R006003 6 mm 3 mm 1,5 mm 50 mm 89 bar 267 bar
T1R635336 6,35 mm (1/4") 3,36 mm 1,495 mm 50 mm 83 bar 250 bar
T1R006004 6 mm 4 mm 1 mm 45 mm 53 bar 160 bar
T1R008005 8 mm 5 mm 1,5 mm 30 mm 61 bar 185 bar
T1R008006 8 mm 6 mm 1 mm 50 mm 38 bar 114 bar
T1R952005 9,52 mm (3/8") 5 mm 2,26 mm 50 mm 83 bar 250 bar
*other colours subject to stock availability. For a minimum quantity Castello by ARaymond produces according to RAL chart (RAL table) or customer's requirements.
TOLERANCE

Tolerance on external diameter as per DIN 73378 Norm:


Ø Ext 3 mm - 10 mm: +/- 0,10 mm
Ø Ext 11 mm - 20 mm: +/- 0,15 mm


Upon request Castello by ARaymond can deliver tubes with higher precision tolerances.


MARKING
Standard marking is:

DIN 73378 - 8x1 mm - PA 11 HL - C.BIO - 03002146 - 19 - 157 - 10:30:32
TEMPERATURE RANGE
From -60° C
to + 130° C
CHEMICAL RESISTANCE
Check the table
ROLL SIZE

0025 25 mt
0050 50 mt
0100 100 mt

Tolerance on roll length +/- 2%
PRESSURE VARIATION
As function of temperature
% PRESS. TEMP
100% 23° C
81% 30° C
61% 40° C
50% 50° C
44% 60° C
39% 70° C
34% 80° C
31% 90° C
28% 100° C
26% 110 C
23% 120° C
21% 130° C

It is forbidden to use Castello by ARaymond tubes and coils in food and medical applications.